Blog

i-STAT Cartridges for COVID-19 Patient Management

Immediate Results at Patients’ Bedside

The i-STAT cartridges are specifically designed for critical diagnostic needs, particularly during outbreaks when the control of patient volume is crucial. By accelerating the availability of diagnostic test results, the i-STAT analyzer allows healthcare professionals to make rapid decisions, enhancing the quality of care and improving system efficiency. The use of minimal whole blood samples and capacity to monitor multiple parameters at once promote a faster turnaround time for patients as well.

Testing Flexibility

With its wide array of cartridges, the i-STAT analyzer can efficiently perform diagnostics for coagulation, arterial blood gases, chemistry, cardiac markers, electrolytes, and hematology. Majority of the COVID-19 related deaths are for patients who were already suffering from previous conditions such as lung cancer, high blood, diabetes, and heart disease. With this in mind, i-STAT has particular cartridges that can provide results for parameters that are vital for COVID-19 patient monitoring.
 

  • Text Hover

CG8+

(Na, K, iCa, Glu, Hct, Hgb, pH, PCO2, PO2, TCO2, HCO3, Base Excess (BE), sO2)
For patients who have severe pneumonia, acute respiratory distress syndrome, or diabetes, CG8+’s capability to test blood gases, electrolytes and glucose can effectively monitor their conditions.

  • Text Hover

CHEM8+

(Na, K, Cl, TCO2, Anion Gap, iCa, Glu, BUN/Urea, Crea, Hct, Hgb)
Dialysis patients need to have their chemistries consistently in surveillance. With CHEM8+’s extensive chemistry parameters, the i-STAT can fulfill this function in just 2 minutes.

  • Text Hover

CG4+

(Lactate, pH, PCO2, PO2, TCO2, HCO3, Base Excess (BE), sO2)
The patients in the ICU who are under septic shock require certain parameters such as blood gases and lactate to be monitored, which can be achieved through the CG4+ test cartridge.

  • Text Hover

Cardiac Markers

(cTnI, BNP, CK-MB)
With heart disease as one of the top reasons of death for COVID-19 patients, parameters such as troponin I are necessary to monitor. With our cTnI, BNP, and CK-MB cardiac markers, the i-STAT can deliver these results in just 5 – 10 minutes.

As our country continues to face the coronavirus outbreak, hospitals nationwide are in crucial need of fast and reliable technologies that could ease their workload significantly. With these i-STAT cartridges, healthcare practitioners are enabled to make crucial decisions in minutes while effectively managing the rising influx of patients.

If you are interested in upgrading your hospital’s diagnostic capability, we’ve attached a quotation request form below.